you are on a solaris box, in on the console, and you cant get any response
do a
#.
that should sort it out
Wednesday, 13 May 2009
cdpinfo and cdpinfo script
Display Cisco Discovery Protocol packet information via tcpdump or snoop. This information includes the name of the network switch the network interface is connected to, plus the port number, vlan, and duplex of the port.
#!/bin/ksh
#
# C D P I N F O . K S H
#
# Script to get the CDP packet from a Cisco switch
#
cdpinfo() {
nic=$1
#
# e1000 driver, special case
IFS="$OLDIFS"
if [ "$(echo "$nic" | grep "e1000")" ]
then
driver=e1000g
instance=`echo "$nic" | sed 's/e1000g//g'`
else
# now work out the speed/duplex/link, etc
driver=`echo $nic | sed 's/\([^0-9]*\)[0-9]*/\1/'`
instance=`echo $nic | sed 's/[^0-9]*\([0-9]*\)/\1/'`
fi
if [ "$driver" != "le" -a "$driver" != "qe" ]; then
if [ "$driver" = "ge" ]; then
advnegname="adv_1000autoneg_cap"
lpnegname="lp_1000autoneg_cap"
else
advnegname="adv_autoneg_cap"
lpnegname="lp_autoneg_cap"
fi
if [ "$driver" != "dmfe" -a "$driver" != "bge" -a "$driver" != e1000g -a "$d
river" != nge ]; then
# set the instance
/usr/sbin/ndd -set /dev/$driver instance $instance
# dmfe/bge/e1000/nge cards don't support the link provider
# (lp_*_cap) variables, ce uses kstat
if [ "$driver" = "ce" ]; then
lpneg=`kstat -p -m $driver -i $instance -s lp_cap_autoneg | awk '{print
$NF}'`
else
lpneg=`/usr/sbin/ndd /dev/$driver $lpnegname`
fi
case $lpneg in
0) lpneg=none ;;
1) lpneg=auto ;;
esac
else
# use the individual instance /dev entries
olddriver=$driver
driver="$driver$instance"
# set to unknown as per above
lpneg=`/usr/sbin/ndd /dev/$driver $lpnegname`
case $lpneg in
0) lpneg=none ;;
1) lpneg=auto ;;
esac
fi
advneg=`/usr/sbin/ndd /dev/$driver $advnegname`
case $advneg in
0) advneg=none ;;
1) advneg=auto ;;
esac
if [ "$driver" = "ce" ]; then
linkstatus=`kstat -p -m $driver -i $instance -s link_up | awk '{print $NF}
'`
else
linkstatus=`/usr/sbin/ndd /dev/$driver link_status`
fi
case $linkstatus in
0) linkstatus=down ;;
1) linkstatus=up ;;
esac
if [ "$driver" = "ce" ]; then
linkspeed=`kstat -p -m $driver -i $instance -s link_speed | awk '{print $N
F}'`
else
linkspeed=`/usr/sbin/ndd /dev/$driver link_speed`
fi
case $linkspeed in
0) linkspeed=10 ;;
1) linkspeed=100 ;;
esac
if [ "$driver" = "ce" ]; then
linkmode=`kstat -p -m $driver -i $instance -s link_duplex | awk '{print $N
F}'`
elif [ "$olddriver" = "bge" ]; then
linkmode=`kstat -p -m $olddriver -i $instance -s duplex | awk '{print $NF}
'`
else
linkmode=`/usr/sbin/ndd /dev/$driver link_mode`
fi
case $linkmode in
0) linkmode=HDX ;;
1) linkmode=FDX ;;
2) linkmode=FDX ;;
full) linkmode=FDX ;;
esac
else
advneg="????"
lpneg="????"
linkstatus="????"
linkspeed=10
linkmode=HDX
fi
# this runs the snoop and extracts the hexdump of the packet,
# splits the 4 digit strings into 2 digit strings and makes the
# hex upper case
snoopcriteria="ether 01:00:0c:cc:cc:cc and ether[20:2] = 0x2000"
switchid="??????????"; port="?/??"; duplex="???"; vlan="????";
snoop -x 0 -c 1 -d $nic $snoopcriteria 2>&1 > /tmp/.cdpinfo.ksh.$$ 2>&1 &
# get the pids, kick off the alarm and wait for the command to exit
cmdpid=$!
(sleep 65; kill $cmdpid > /dev/null 2>&1) &
alarmpid=$!
wait $cmdpid > /dev/null 2>&1
kill $alarmpid > /dev/null 2>&1
# otherwise, go ahead and parse the cdp packet
set -A rawpacket ` \
grep '^[ ][ ]*[0-9][0-9]*' /tmp/.cdpinfo.ksh.$$ | \
cut -c8-46 | \
sed 's/\([0-9a-f][0-9a-f]\)\([0-9a-f][0-9a-f]\)/\1 \2/g' | \
tr '[a-f]' '[A-F]'`
typeset -i arraylength=${#rawpacket[*]}
typeset -i i=0 id=0 len=0 subi=0 boolean=0 num=0
# grab the CDP version
typeset -i cdpver=${rawpacket[$(echo "ibase=16; 16" | bc)]}
# skip to location 1A in the packet
i=$(echo "ibase=16; 1A"|bc)
while [ $i -lt $arraylength ]; do
id=$(echo "ibase=16; ${rawpacket[$i]}*100+${rawpacket[$i+1]}" | bc)
len=$(echo "ibase=16; ${rawpacket[$i+2]}*100+${rawpacket[$i+3]}" | bc)
string=""
case $id in
1) subi=4
while [ $subi -lt $len ]; do
char=$(echo "ibase=16; obase=8; ${rawpacket[$i+$subi]}" | bc)
string="${string}\0${char}"
subi=$subi+1
done
switchid=$(print $string)
switchid=$(echo $switchid | sed 's/[^(]*[(]\([^)]*\)[)]/\1/' | sed s'/G
igabitEthernet//g')
;;
3) subi=4
while [ $subi -lt $len ]; do
char=$(echo "ibase=16; obase=8; ${rawpacket[$i+$subi]}" | bc)
string="${string}\0${char}"
subi=$subi+1
done
port=$(print $string | sed s'/GigabitEthernet//g')
;;
10) subi=4; num=0
while [ $subi -lt $len ]; do
num=$(echo "ibase=16; $num*100+${rawpacket[$i+$subi]}" | bc)
subi=$subi+1
done
vlan=$num
;;
11) boolean=$(echo "ibase=16; ${rawpacket[$i+4]}" | bc)
if [ $boolean == 0 ]; then
duplex="HDX"
else
duplex="FDX"
fi
esac
i=$i+$len
done
# cdp version 1 doesn't tell you the duplex
if [ $cdpver = 1 ]; then
duplex="???"
fi
# remove the tempfile
rm -f /tmp/.cdpinfo.ksh.$$
}
#
# MAIN
#
# print header
echo "NIC IP_ADDR SWITCHID PORT VLAN LINK SPEED SWITCH_N/D HOST_N/D" | awk '{pri
ntf("%-8s %-13s %-34s %-8s %-8s %-8s %-10s %-13s %-13s\n", $1, $2, $3, $4, $5, $
6, $7, $8, $9)}'
echo "--------------------------------------------------------------------------
--------------------------------------------"
echo
#
# The old version assumes it needs to be plumbed up
#if [ $# = 0 ]; then
# nics=`ifconfig -a|grep '^[a-z][a-z]*[0-9]' \
# | grep -v lo0 \
# | egrep -v ':[0-9]: ' \
# | grep UP \
# | cut -d: -f1`
#else
# nics=$@
#fi
NIC_DATA=$(/usr/bin/kstat -p -c net | egrep -v "lpfc|streams|lo0|dls|ip|ipsec|tc
p|udp" | egrep "link_up|duplex" | grep -v link_duplex | awk -F: '{ printf("%s%s
%s\n",$1,$2,$4)}' | sort -u | sed -e s'/link_up//g' -e s'/duplex//g')
OLDIFS="$IFS"
IFS='
'
# now, cycle through the nics
for LINE in `echo "$NIC_DATA"`
do
NIC=`echo "$LINE" | awk '{print($1)}'`
LINK=`echo "$LINE" | awk '{print($2)}'`
#echo "NIC = $NIC"
#echo "LINK = $LINK"
if [ "$LINK" != "1" ] && [ "$LINK" != "full" ]
then
echo "$NIC LINK_DOWN" | awk '{printf("%-8s %-13s\n", $1, $2)}'
continue
else
cdpinfo ${NIC}
IFCONFIG=`ifconfig ${NIC} 2> /dev/null | grep inet | awk '{print($2)}'`
if [ ! "$IFCONFIG" ]
then
IFCONFIG="NOT_PLUMBED"
fi
echo "$NIC $IFCONFIG ${switchid} ${port} ${vlan} ${linkstatus} ${linkspeed
} ${lpneg}/${duplex} ${advneg}/${linkmode}" | awk '{printf("%-8s %-13s %-34s %-8
s %-8s %-8s %-10s %-13s %-13s\n", $1, $2, $3, $4, $5, $6, $7, $8, $9)}'
fi
done
#!/bin/ksh
#
# C D P I N F O . K S H
#
# Script to get the CDP packet from a Cisco switch
#
cdpinfo() {
nic=$1
#
# e1000 driver, special case
IFS="$OLDIFS"
if [ "$(echo "$nic" | grep "e1000")" ]
then
driver=e1000g
instance=`echo "$nic" | sed 's/e1000g//g'`
else
# now work out the speed/duplex/link, etc
driver=`echo $nic | sed 's/\([^0-9]*\)[0-9]*/\1/'`
instance=`echo $nic | sed 's/[^0-9]*\([0-9]*\)/\1/'`
fi
if [ "$driver" != "le" -a "$driver" != "qe" ]; then
if [ "$driver" = "ge" ]; then
advnegname="adv_1000autoneg_cap"
lpnegname="lp_1000autoneg_cap"
else
advnegname="adv_autoneg_cap"
lpnegname="lp_autoneg_cap"
fi
if [ "$driver" != "dmfe" -a "$driver" != "bge" -a "$driver" != e1000g -a "$d
river" != nge ]; then
# set the instance
/usr/sbin/ndd -set /dev/$driver instance $instance
# dmfe/bge/e1000/nge cards don't support the link provider
# (lp_*_cap) variables, ce uses kstat
if [ "$driver" = "ce" ]; then
lpneg=`kstat -p -m $driver -i $instance -s lp_cap_autoneg | awk '{print
$NF}'`
else
lpneg=`/usr/sbin/ndd /dev/$driver $lpnegname`
fi
case $lpneg in
0) lpneg=none ;;
1) lpneg=auto ;;
esac
else
# use the individual instance /dev entries
olddriver=$driver
driver="$driver$instance"
# set to unknown as per above
lpneg=`/usr/sbin/ndd /dev/$driver $lpnegname`
case $lpneg in
0) lpneg=none ;;
1) lpneg=auto ;;
esac
fi
advneg=`/usr/sbin/ndd /dev/$driver $advnegname`
case $advneg in
0) advneg=none ;;
1) advneg=auto ;;
esac
if [ "$driver" = "ce" ]; then
linkstatus=`kstat -p -m $driver -i $instance -s link_up | awk '{print $NF}
'`
else
linkstatus=`/usr/sbin/ndd /dev/$driver link_status`
fi
case $linkstatus in
0) linkstatus=down ;;
1) linkstatus=up ;;
esac
if [ "$driver" = "ce" ]; then
linkspeed=`kstat -p -m $driver -i $instance -s link_speed | awk '{print $N
F}'`
else
linkspeed=`/usr/sbin/ndd /dev/$driver link_speed`
fi
case $linkspeed in
0) linkspeed=10 ;;
1) linkspeed=100 ;;
esac
if [ "$driver" = "ce" ]; then
linkmode=`kstat -p -m $driver -i $instance -s link_duplex | awk '{print $N
F}'`
elif [ "$olddriver" = "bge" ]; then
linkmode=`kstat -p -m $olddriver -i $instance -s duplex | awk '{print $NF}
'`
else
linkmode=`/usr/sbin/ndd /dev/$driver link_mode`
fi
case $linkmode in
0) linkmode=HDX ;;
1) linkmode=FDX ;;
2) linkmode=FDX ;;
full) linkmode=FDX ;;
esac
else
advneg="????"
lpneg="????"
linkstatus="????"
linkspeed=10
linkmode=HDX
fi
# this runs the snoop and extracts the hexdump of the packet,
# splits the 4 digit strings into 2 digit strings and makes the
# hex upper case
snoopcriteria="ether 01:00:0c:cc:cc:cc and ether[20:2] = 0x2000"
switchid="??????????"; port="?/??"; duplex="???"; vlan="????";
snoop -x 0 -c 1 -d $nic $snoopcriteria 2>&1 > /tmp/.cdpinfo.ksh.$$ 2>&1 &
# get the pids, kick off the alarm and wait for the command to exit
cmdpid=$!
(sleep 65; kill $cmdpid > /dev/null 2>&1) &
alarmpid=$!
wait $cmdpid > /dev/null 2>&1
kill $alarmpid > /dev/null 2>&1
# otherwise, go ahead and parse the cdp packet
set -A rawpacket ` \
grep '^[ ][ ]*[0-9][0-9]*' /tmp/.cdpinfo.ksh.$$ | \
cut -c8-46 | \
sed 's/\([0-9a-f][0-9a-f]\)\([0-9a-f][0-9a-f]\)/\1 \2/g' | \
tr '[a-f]' '[A-F]'`
typeset -i arraylength=${#rawpacket[*]}
typeset -i i=0 id=0 len=0 subi=0 boolean=0 num=0
# grab the CDP version
typeset -i cdpver=${rawpacket[$(echo "ibase=16; 16" | bc)]}
# skip to location 1A in the packet
i=$(echo "ibase=16; 1A"|bc)
while [ $i -lt $arraylength ]; do
id=$(echo "ibase=16; ${rawpacket[$i]}*100+${rawpacket[$i+1]}" | bc)
len=$(echo "ibase=16; ${rawpacket[$i+2]}*100+${rawpacket[$i+3]}" | bc)
string=""
case $id in
1) subi=4
while [ $subi -lt $len ]; do
char=$(echo "ibase=16; obase=8; ${rawpacket[$i+$subi]}" | bc)
string="${string}\0${char}"
subi=$subi+1
done
switchid=$(print $string)
switchid=$(echo $switchid | sed 's/[^(]*[(]\([^)]*\)[)]/\1/' | sed s'/G
igabitEthernet//g')
;;
3) subi=4
while [ $subi -lt $len ]; do
char=$(echo "ibase=16; obase=8; ${rawpacket[$i+$subi]}" | bc)
string="${string}\0${char}"
subi=$subi+1
done
port=$(print $string | sed s'/GigabitEthernet//g')
;;
10) subi=4; num=0
while [ $subi -lt $len ]; do
num=$(echo "ibase=16; $num*100+${rawpacket[$i+$subi]}" | bc)
subi=$subi+1
done
vlan=$num
;;
11) boolean=$(echo "ibase=16; ${rawpacket[$i+4]}" | bc)
if [ $boolean == 0 ]; then
duplex="HDX"
else
duplex="FDX"
fi
esac
i=$i+$len
done
# cdp version 1 doesn't tell you the duplex
if [ $cdpver = 1 ]; then
duplex="???"
fi
# remove the tempfile
rm -f /tmp/.cdpinfo.ksh.$$
}
#
# MAIN
#
# print header
echo "NIC IP_ADDR SWITCHID PORT VLAN LINK SPEED SWITCH_N/D HOST_N/D" | awk '{pri
ntf("%-8s %-13s %-34s %-8s %-8s %-8s %-10s %-13s %-13s\n", $1, $2, $3, $4, $5, $
6, $7, $8, $9)}'
echo "--------------------------------------------------------------------------
--------------------------------------------"
echo
#
# The old version assumes it needs to be plumbed up
#if [ $# = 0 ]; then
# nics=`ifconfig -a|grep '^[a-z][a-z]*[0-9]' \
# | grep -v lo0 \
# | egrep -v ':[0-9]: ' \
# | grep UP \
# | cut -d: -f1`
#else
# nics=$@
#fi
NIC_DATA=$(/usr/bin/kstat -p -c net | egrep -v "lpfc|streams|lo0|dls|ip|ipsec|tc
p|udp" | egrep "link_up|duplex" | grep -v link_duplex | awk -F: '{ printf("%s%s
%s\n",$1,$2,$4)}' | sort -u | sed -e s'/link_up//g' -e s'/duplex//g')
OLDIFS="$IFS"
IFS='
'
# now, cycle through the nics
for LINE in `echo "$NIC_DATA"`
do
NIC=`echo "$LINE" | awk '{print($1)}'`
LINK=`echo "$LINE" | awk '{print($2)}'`
#echo "NIC = $NIC"
#echo "LINK = $LINK"
if [ "$LINK" != "1" ] && [ "$LINK" != "full" ]
then
echo "$NIC LINK_DOWN" | awk '{printf("%-8s %-13s\n", $1, $2)}'
continue
else
cdpinfo ${NIC}
IFCONFIG=`ifconfig ${NIC} 2> /dev/null | grep inet | awk '{print($2)}'`
if [ ! "$IFCONFIG" ]
then
IFCONFIG="NOT_PLUMBED"
fi
echo "$NIC $IFCONFIG ${switchid} ${port} ${vlan} ${linkstatus} ${linkspeed
} ${lpneg}/${duplex} ${advneg}/${linkmode}" | awk '{printf("%-8s %-13s %-34s %-8
s %-8s %-8s %-10s %-13s %-13s\n", $1, $2, $3, $4, $5, $6, $7, $8, $9)}'
fi
done
Tuesday, 12 May 2009
Find out the size of a directory with du -sk
eepr0143> du -sk /app/SAD/var
7993507 /app/SAD/var
so there you go - totals up all the files under the dir into a summary, displayed in kilobytes (so here the size is roughly 7.5gb)
7993507 /app/SAD/var
so there you go - totals up all the files under the dir into a summary, displayed in kilobytes (so here the size is roughly 7.5gb)
Monday, 11 May 2009
Troubleshooting a NIC
All the computers in a data center are connected together to form a network . A NIC (Network Interface Card) provides a connection point for a computer. Plug in a network cable, adjust some NIC configuration and some routing configuration and the computer is ready to talk.
When a network goes bad, you need a set of commands to find fast the problem.
First off, obviously is to connect to the server with the problem. If you can't use ssh (or even telnet) to connect through to the management interface, then try logging in to the terminal server. From there you can begin troubleshooting;
run a prtdiag and see if there any hardware issues on the interfaces
check the /var/adm/messages file - for example, if a link keeps going down then up - where does the issue lie? With a cable, a switch port? A NIC?
ndd - for example
ndd /dev/bge1 adv_100fdx_cap link_status link_speed
where
# ndd /dev/interfacename \? --- displays all command options for ndd
# ndd /dev/interfacename link_status --- 0 is down,1 is up.
# ndd /dev/interfacename link_speed --- 0 means 10mbps, 1 means 100mbps
# ndd /dev/hme interfacename --- 0 means half duplex, 1 means full duplex
run a snoop
snoop -d interfacename
this gets all the oputput in promiscuous mode - if transfers are good you get SUCCESS, which would be encouraging...
ifconfig -a
this shows the status of the interface - needs to be UP, RUNNING, BROADCAST, MULTICAST - to determine it is working okay
Look at the traffic that is being seen by that interface. There may be plenty of traffic that is being ignored because it is meant for other hosts. This could mean the cable has been attachd to the wrong virtual network ie. the cable has been plugged into the wrong socket on the firewall.
root@ersds12:>snoop -v -d bge0
Using device /dev/bge (promiscuous mode)
ETHER: ----- Ether Header -----
ETHER:
ETHER: Packet 1 arrived at 11:39:1.67
...
IP: ----- IP Header -----
IP:
IP: Version = 4
...
IP: Source address = 192.168.18.2, 192.168.18.2
IP: Destination address = 224.0.0.18, 224.0.0.18
IP: No options
...
an excellent link for this sort of stuff;
http://www.planetlarg.net/closed-source/net-solaris-health.htm
When a network goes bad, you need a set of commands to find fast the problem.
First off, obviously is to connect to the server with the problem. If you can't use ssh (or even telnet) to connect through to the management interface, then try logging in to the terminal server. From there you can begin troubleshooting;
run a prtdiag and see if there any hardware issues on the interfaces
check the /var/adm/messages file - for example, if a link keeps going down then up - where does the issue lie? With a cable, a switch port? A NIC?
ndd - for example
ndd /dev/bge1 adv_100fdx_cap link_status link_speed
where
# ndd /dev/interfacename \? --- displays all command options for ndd
# ndd /dev/interfacename link_status --- 0 is down,1 is up.
# ndd /dev/interfacename link_speed --- 0 means 10mbps, 1 means 100mbps
# ndd /dev/hme interfacename --- 0 means half duplex, 1 means full duplex
run a snoop
snoop -d interfacename
this gets all the oputput in promiscuous mode - if transfers are good you get SUCCESS, which would be encouraging...
ifconfig -a
this shows the status of the interface - needs to be UP, RUNNING, BROADCAST, MULTICAST - to determine it is working okay
Look at the traffic that is being seen by that interface. There may be plenty of traffic that is being ignored because it is meant for other hosts. This could mean the cable has been attachd to the wrong virtual network ie. the cable has been plugged into the wrong socket on the firewall.
root@ersds12:>snoop -v -d bge0
Using device /dev/bge (promiscuous mode)
ETHER: ----- Ether Header -----
ETHER:
ETHER: Packet 1 arrived at 11:39:1.67
...
IP: ----- IP Header -----
IP:
IP: Version = 4
...
IP: Source address = 192.168.18.2, 192.168.18.2
IP: Destination address = 224.0.0.18, 224.0.0.18
IP: No options
...
an excellent link for this sort of stuff;
http://www.planetlarg.net/closed-source/net-solaris-health.htm
Friday, 8 May 2009
legato - some commands - nsrwatch
nsrwatch - this is the one to see a running status of drives and tapes mounted, backups going on, messages etc
the proper format is
nsrwatch -s servername
the proper format is
nsrwatch -s servername
Thursday, 7 May 2009
assigning symmetrix devices to extend a filesystem
when extending filesystems with symmetrix disks
worth checking that the new disks come from the same Symmetrix boxes as the established symmetrix disks - Otherwise they can't be put in the diskgroup for failover.
this is so new devices can be assigned easily in the event of a failover (cluster)
worth checking that the new disks come from the same Symmetrix boxes as the established symmetrix disks - Otherwise they can't be put in the diskgroup for failover.
this is so new devices can be assigned easily in the event of a failover (cluster)
Tuesday, 28 April 2009
Subscribe to: